33482S2W

1,232.00

COMPACT AIR CIRCUIT BRAKER -NS

SKU: 33482S2W Categories: ,

Description

Sale Price 33482S2W Compact breakers, Schneider Electric COMPACT AIR CIRCUIT BRAKER -NS

Range Compact
Range of product NS630b…1600
Product or component type Circuit breaker
Device short name Compact NS1000N
Device application Distribution
Poles description 3P
Protected poles description 3t
Network type AC
Breaking capacity code N
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name Micrologic 2.0
Trip unit technology Electronic
Trip unit rating 1000 A ( 50 ?C )
Complementary
Network frequency 50/60 Hz
Control type Toggle
Rotary handle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
(In) rated current up to 65 ?C 1000 A ( 50 ?C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Aug 8, 2019
1
Circuit breaker CT rating 1000 A
Breaking capacity 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity Ics 30 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Ics 40 kA 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
Auxiliary contact composition 1 NO/NC
Mechanical durability 10000 cycles
Electrical durability 2000 cycles IEC 60947-2 690 V In AC 50/60 Hz
4000 cycles IEC 60947-2 690 V In/2 AC 50/60 Hz
5000 cycles IEC 60947-2 440 V In AC 50/60 Hz
6000 cycles IEC 60947-2 440 V In/2 AC 50/60 Hz
Local signalling Positive contact indication
[Icw] rated short-time withstand current 19.2 kA
Trip unit protection functions LI
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.4…1 x In
Long time delay adjustment type Adjustable 9 settings
[Tr] long-time delay adjustment range 0.5…24 s 6 x Ir
0.7…16.6 s 7.2 x Ir
12.5…600 s 1.5 x Ir
Thermal memory 20 mn
Instantaneous pick-up adjustment type
Ii
Adjustable
Instantaneous pick-up adjustment
range
1.5…10 x Ir
Integrated instantaneous protection 40 kA
Height 327 mm
Width 210 mm
Depth 147 mm
Environment
Standards IEC 60947-2
Product certifications ASEFA
ASTA
Power losses 22 W
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Pollution degree 3 conforming to IEC 60947
Ambient air temperature for operation -25…70 ?C
Ambient air temperature for storage -50…85 ?C|Industry Supply Chain|InduSup| COMPACT AIR CIRCUIT BRAKER -NS

Range Compact
Range of product NS630b…1600
Product or component type Circuit breaker
Device short name Compact NS1000N
Device application Distribution
Poles description 3P
Protected poles description 3t
Network type AC
Breaking capacity code N
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name Micrologic 2.0
Trip unit technology Electronic
Trip unit rating 1000 A ( 50 ?C )
Complementary
Network frequency 50/60 Hz
Control type Toggle
Rotary handle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
(In) rated current up to 65 ?C 1000 A ( 50 ?C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Aug 8, 2019
1
Circuit breaker CT rating 1000 A
Breaking capacity 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity Ics 30 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Ics 40 kA 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
Auxiliary contact composition 1 NO/NC
Mechanical durability 10000 cycles
Electrical durability 2000 cycles IEC 60947-2 690 V In AC 50/60 Hz
4000 cycles IEC 60947-2 690 V In/2 AC 50/60 Hz
5000 cycles IEC 60947-2 440 V In AC 50/60 Hz
6000 cycles IEC 60947-2 440 V In/2 AC 50/60 Hz
Local signalling Positive contact indication
[Icw] rated short-time withstand current 19.2 kA
Trip unit protection functions LI
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.4…1 x In
Long time delay adjustment type Adjustable 9 settings
[Tr] long-time delay adjustment range 0.5…24 s 6 x Ir
0.7…16.6 s 7.2 x Ir
12.5…600 s 1.5 x Ir
Thermal memory 20 mn
Instantaneous pick-up adjustment type
Ii
Adjustable
Instantaneous pick-up adjustment
range
1.5…10 x Ir
Integrated instantaneous protection 40 kA
Height 327 mm
Width 210 mm
Depth 147 mm
Environment
Standards IEC 60947-2
Product certifications ASEFA
ASTA
Power losses 22 W
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Pollution degree 3 conforming to IEC 60947
Ambient air temperature for operation -25…70 ?C
Ambient air temperature for storage -50…85 ?C

Additional information

Weight 14 kg
Dimensions 10 × 15 × 47 cm
Coil Voltage Operation
breaking Capacity

Current

Pole

3

PROTECTED POLES

Reviews

There are no reviews yet.

Be the first to review “33482S2W”
error: Content is protected !!